ALM-10246 Antenna and TMA Control Unit Communication Alarm

Description

This alarm is reported when the Antenna and TMA Control Unit and the TMU communicates abnormally.

Attribute

Alarm ID Alarm Severity Alarm Type
10246 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

67:DATU

98:GATM

3 Board No.

Number of the fault board

0-35:DATU/GATM

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The Antenna and TMA Control Unit cannot be maintained.

System Actions

None.

Possible Causes

  • The Antenna and TMA Control Unit is not installed.
  • The communication link is faulty between the TMU and the Antenna and TMA Control Unit.

Procedure

  1. Check if the faulty Antenna and TMA Control Unit is powered on and in position.

    Y=>Go to Step 3.

    N=>Go to Step 2.

  2. Power on the Antenna and TMA Control Unit or install the board.

    Y=>The alarm is cleared. Alarm handling is complete.

    N=>Go to Step 3.

  3. Check if the communication cable of the Antenna and TMA Control Unit is connected properly.
    1. Check if the CBUS3 is connected properly.

      Y=>Go to Step 4.

      N=>Go to Step b.

    2. Connect the CBUS3 properly. Check if the alarm is cleared.

      Y=>The alarm is cleared. Alarm handling is complete.

      N=>Go to Step 4.

  4. Plug out or replace the other boards in the CBUS3 link .Check if the alarm is cleared.

    Y=>The alarm handling is complete.

    N=>Go to Step 5.

  5. Replace the faulty Antenna and TMA Control Unit. Check if the alarm is cleared.

    Y=>The alarm is cleared. The alarm handling is complete.

    N=> The alarm is not cleared. Please contact Huawei Customer Service Center.