ALM-10270 RET Configuration Data Lost Alarm

Description

This alarm is reported when the configuration data of the Remote Electrical Tilt (RET) antenna is lost.

Attribute

Alarm ID Alarm Severity Alarm Type
10270 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

67:DATU

98:GATM

3 Board No.

Number of the fault board

0-35:DATU/GATM

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:RET antenna communication alarm 1

1:RET antenna communication alarm 2

2:RET antenna communication alarm 3

35:RET antenna communication alarm 35

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

If the RET antenna is not initialized or the configuration data of the RET antenna is lost, the RET antenna cannot work properly.

System Actions

None.

Possible Causes

The RET antenna is not initialized or the configuration data of the RET antenna is lost.

Procedure

  1. Load the configuration file of the RET antenna in the LMT.

    Load the configuration file of the RET antenna in the LMT and check whether the alarm is cleared.

    Y=> The alarm is cleared. The alarm handling is complete.

    N=> Go to Step 2.

  2. Replace the faulty RET antenna controller. Check if the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is complete.

    N=>Go to Step 3.

  3. Replace the faulty RET antenna. Check if the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is complete.

    N=>The alarm is not cleared. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.