ALM-10282 TMA Current High Prompt Alarm

Description

This alarm is generated when the current feeding to the TMA is too high.

Attribute

Alarm ID Alarm Severity Alarm Type
10282 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

67:DATU

98:GATM

3 Board No.

Number of the fault board

0-35:DATU/GATM

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

Sub No.0:TMA high feed current alarm 1

Sub No.1:TMA high feed current alarm 2

Sub No.2:TMA high feed current alarm 3

Sub No.3:TMA high feed current alarm 4

Sub No.4:TMA high feed current alarm 5

Sub No.5:TMA high feed current alarm 6

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

Once the alarm is generated, the TMA or DATU may be damaged.

System Actions

If the current exceeds a predefined threshold, the system may disconnect the feeding circuit.

Possible Causes

The TMA hardware is faulty.

Procedure

  1. Check whether the power cable and its connector are securely connected.
    1. Check whether the power cable and its connector are securely connected.

      Y=> Go to step 2.

      N=> Go to step b.

    2. Reconnect the cable and the connector.

      Check whether the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to step 2.

  2. Check the TMA.

    Shut down the TMA and restart it. Then, check whether the alarm is cleared.

    Y=> The alarm is cleared. The alarm handling is complete.

    N=> Go to step 3.

  3. Replace the TMA.

    Replace the TMA, and then check whether the alarm is cleared.

    Y=> The alarm is cleared. The alarm handling is complete.

    N=> The alarm persists. Please contact Huawei Customer Service Center.