ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 74:DHEU 95:DTCU |
3 | Board No. | Number of the fault board 0:DHEU/DTCU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0:Built-in temperature sensor of the DHEC 1:External temperature sensor connected to the DHEU This sensor measures the temperature on the air outlet of the cabinet. 2:External temperature sensor connected to the DHEU This sensor measures the temperature on the air inlet of the cabinet. 3:External temperature sensor connected to the DHEU This sensor measures the environment temperature. |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 15:BTS3012AE; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Y=> Go to step 3.
N=> Go to b.
Check whether the alarm is cleared after the reconnection.
Y=> The alarm is cleared. The alarm handling is complete.
N=> The alarm persists. Go to step 3.
Check whether the alarm is cleared after the replacement.
Y=> The alarm is cleared. The alarm handling is complete.
N=> The alarm persists. Please contact Huawei Customer Service Center.