ALM-11286 Version rollback alarm

Description

The version in section B is rolled back to that in section A while its verification appears error.

Attribute

Alarm ID Alarm Severity Alarm Type
11286 Minor Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

86:DPTU

3 Board No.

Number of the fault board

1: DPTU on COMM1

2: DPTU on COMM2

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

Version mismatch alarm may accompany this alarm.

System Actions

None.

Possible Causes

  • Content of versionB in the flash memory of the DPTU is erased accidentally.
  • Flash in the DPTU board is damaged.

Procedure

  1. Load the required DPTU software to the current BTS and activate the loaded software. Check whether the alarm is cleared.

    Y=> The alarm handling is complete.

    N=> Go to step 2.

  2. Replace the DPTU. Reload the software and activate the loaded software. Then check whether the alarm is cleared.

    Y=>The alarm handling is complete.

    N=>Please contact Huawei Customer Service Center.