ALM-11364 DPTU board communication alarm

Description

This alarm is reported when the DPTU can't commucation with DPTU properly

Attribute

Alarm ID Alarm Severity Alarm Type
11364 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

86:DPTU

3 Board No.

Number of the fault board

1: DPTU on COMM1

2: DPTU on COMM2

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The maintenance on the DPTU fails.

System Actions

None.

Possible Causes

  • The corresponding DPTU is not installed.
  • The communications between the corrresponding DPTU and the main control module is not normal.

Procedure

  1. Check whether the DPTU is powered on.

  2. Check whether the DPTU is securely inserted.

  3. If the DPTU is powered on and securely inserted, replace the DPTU.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.