ALM-11790 GPS receiver communication alarm

Description

Communication between GPS receiver and DTMU abnormal.

Attribute

Alarm ID Alarm Severity Alarm Type
11790 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

99:DGPS

3 Board No.

Number of the fault board

0-35:DGPS

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The GPS receiver does not work.

System Actions

None.

Possible Causes

  • The configuration of the GPS or RGPS is inconsistent with the physical configuration.
  • The hardware of the GPS receiver is faulty.
  • The main control module is faulty.

Procedure

  1. Check the configuration and physical type of the GPS or RGPS.
    1. Check whether the configuration and physical type of the GPS or RGPS are consistent.

      Y=> Go to step 2;

      N=> Go to step b.

    2. Reconfigure the type of the receiver as GPS or RGPS, and then check whether the alarm is cleared.

      Y=> The alarm handing ends;

      N=> Go to step 2.

  2. Check whether the DGPS board is in position.
    1. Check whether the corresponding DGPS board is in position.

      Y=> Go to step 3;

      N=> Go to step b.

    2. Reinstall the DGPS board, and then check whether the alarm is cleared.

      Y=> The alarm handing ends;

      N=> Go to step 3.

  3. Replace the DGPS board, and then check whether the alarm is cleared.

    Y=> The alarm handing ends;

    N=> Go to step 4.

  4. Replace the DTMU board, and then check whether the alarm is cleared.

    Y=> The alarm handing ends;

    N=> Contact Huawei Customer Service Center.