ALM-12260 Board Type Mismatch Alarm

Description

The board in the slot is not GPS board.

Attribute

Alarm ID Alarm Severity Alarm Type
12260 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

99:DGPS

3 Board No.

Number of the fault board

0-35:DGPS

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

67:The board inserted into the slot is DATU;

70:The board inserted into the slot is DEMU;

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The GPS board does not work.

System Actions

None.

Possible Causes

The board in the slot is not the GPS board.

Procedure

  1. Check whether the board in the slot is DGPS

    Y=> Go to Step 2.

    N=> Go to Step 3.

  2. Reset the DGPS board, check if the alarm is cleared.

    Y=>The alarm is cleared. The alarm handling is complete.

    N=>The alarm is not cleared. Please contact Huawei Customer Service Center.

  3. Replace the board in the slot by DGPS. check if the alarm is cleared.

    Y=>The alarm is cleared. The alarm handling is complete.

    N=>The alarm is not cleared. Please contact Huawei Customer Service Center.