ALM-12298 Site Reset Alarm

Description

The alarm is reported when the BTS starts up.

Attribute

Alarm ID Alarm Severity Alarm Type
12298 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

67:BTS3900B module

3 Board No.

Number of the fault board

0:BTS3900B module

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

29:BTS3900B;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

The alarm is automatically cleared three minutes after it occurs.

Possible Causes

The BTS resets.

Procedure

  1. Check whether the BTS is reset manually.

    Y => The alarm is automatically cleared in three minutes. End the alarm handling.

    N => Go to procedure 2.

  2. Check whether the reset of the BTS is caused by the reset of the BSC.

    Query the OML message to check whether the BSC has been reset.

    Y => The alarm is automatically cleared in three minutes. End the alarm handling.

    N => Go to procedure 3.

  3. Check whether the BTS has power failure.

    Y => The power-off reset occurs on the BTS. The power supply to the BTS may be abnormal. End the alarm handling.

    N => The power-off reset does not occur on the BTS. The alarm may be caused by faulty hardware. Contact Huawei Customer Service Center.