ALM-12310 Radio Link Abnormal Alarm

Description

This alarm is reported when the BTS detects continuous RL abnormalities. RL abnormalities include the following situations: a. Warning for abnormal channel activation. It indicates that the channel types or states of the BTS is inconsistent with those of the BSC. b. Warning for abnormal channel release. It indicates that the proportion of abnormal channel release exceeds the relevant alarm threshold. c. The traffic volume of the BCCH TRX is zero. The traffic volume of the BCCH TRX is zero in a continuous testing period. The default period is four hours. You can define the period. d. Warning for power level imbalance between UL and DL. It indicates that the UL power level and the DL power level deviate from each other greatly.

Attribute

Alarm ID Alarm Severity Alarm Type
12310 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

67:BTS3900B module

3 Board No.

Number of the fault board

0:BTS3900B module

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:warning for abnormal channel activation

1:warning for abnormal channel release

2:warning for no traffic on main BCCH

3:warning for power level imbalance between UL and DL

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

29:BTS3900B;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

13 Cause of the Fault

Cause of the fault

0:warning for abnormal channel activation

1:warning for abnormal channel release

2:warning for no traffic on main BCCH

3:warning for power level imbalance between UL and DL

Impact on the System

The traffic statistics counters and cell traffic load where the alarm is generated are directly impacted, the handover success ratio is lowered.

System Actions

The system starts auto detection after the alarm is generated. The alarm will disappear when the conditions are met.

Possible Causes

  • The channel types or states of the BTS is inconsistent with those of the BSC.
  • The proportion of abnormal channel release exceeds the relevant alarm threshold.
  • There is no traffic detected on the main BCCH within the set period.
  • The BTS detects that the UL power level and the DL power level deviate from each other greatly.

Procedure

  1. Check the channel configuration of the main BCCH.

    Check whether the main BCCH is configured with the TCH.

    Y => Go to procedure 2.

    N => Check whether the TCHs are converted to the PDCHs. If yes, the alarm handling is complete. If not, go to procedure [2].

  2. Originate a call through the main BCCH.

    Lock the frequency of the test MS to the frequency of the main BCCH and originates a call. Check whether the alarm is cleared:

    Y => The alarm is cleared. End the alarm handling.

    N => The alarm is not cleared. Go to procedure 3.

  3. Reset the BTS.

    Reset the Site in Level 4 on the SMT or the LMT. Check whether the alarm is cleared.

    Y => The alarm is cleared. End the alarm handling.

    N => The alarm is not cleared. Go to procedure 4.

  4. Replace the BTS3900B module.

    Replace the BTS3900B Module that is faulty. Check whether the alarm is cleared.

    Y => The alarm is cleared. End the alarm handling.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.