ALM-12812 SFP Link Fault

Description

This alarm is reported when LOF or LOS occurs on the local or remote SFP ports.

Attribute

Alarm ID Alarm Severity Alarm Type
12812 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

107:BTS3900E

3 Board No.

Number of the fault board

0-3: BTS3900E

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:SFP0 port remote alarm

1:SFP1 port remote alarm

2:SFP0 port local alarm

3:SFP1 port local alarm

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

30:BTS3900E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

13 Cause of the Fault

Cause of the fault

0:SFP0 port remote alarm

1:SFP1 port remote alarm

2:SFP0 port local alarm

3:SFP1 port local alarm

Impact on the System

When the alarm is generated, the communication between the modules of the BTS3900E fails.

System Actions

None.

Possible Causes

The SFP port is abnormal.

Procedure

  1. Check the optical cable.

    Replace the optical cable with a new one, and then check whether the alarm is cleared.

    Y=> The alarm is cleared. End the alarm handling.

    N=> The alarm is not cleared. Go to 2.

  2. Replace the optical module.

    Y=> The alarm is cleared. End the alarm handling.

    N=> The alarm is not cleared. Go to 3.

  3. Connect two SFP ports to form a loopback.

    Connect two SFP ports on the main BTS3900E so that the BTS3900E forms a self-loop, and then check whether the alarm is cleared.

    Y=> The alarm is cleared, which indicates that the BTS3900E module which connects to the SFP port is faulty. Go to 4.

    N=> The alarm is not cleared, which indicates that the SFP port on the main BTS3900E module is faulty. Go to 4.

  4. Replace the BTS3900E module.

    Replace the BTS3900E Module, and then check whether the alarm is cleared.

    Y=> The alarm is cleared. End the alarm handling.

    N=> The alarm is not clear. Contact Huawei Customer Service Center.