ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 107:BTS3900E |
3 | Board No. | Number of the fault board 0-3: BTS3900E |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0:Warning of abnormal channel activation 1:Warning of abnormal channel release 2:Warning of no traffic on the main BCCH 3:Warning of imbalanced uplink and downlink levels |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 30:BTS3900E; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
13 | Cause of the Fault | Cause of the fault 0:warning for abnormal channel activation 1:warning for abnormal channel release 2:warning for no traffic on main BCCH 3:warning for power level imbalance between UL and DL |
The system starts auto detection after the alarm is generated. The alarm will disappear when the conditions are met.
Check whether the main BCCH is configured with the TCH channels.
Y => Go to procedure 2.
N => Check whether the TCHs are converted to the PDCHs. If yes, the alarm handling is complete. If not, go to procedure [2].
Lock the frequency of the test MS to the frequency of the main BCCH and originate a call. Check whether the alarm is cleared:
Y => The alarm is cleared. End the alarm handling.
N => The alarm is not cleared. Go to procedure 3.
Reset the Site in Level 4 on the BSC or the LMT. Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to procedure 4.
Replace the 3900E Module that is faulty. Check whether the alarm is cleared.
Y => The alarm is cleared. End the alarm handling.
N => The alarm is not cleared. Contact Huawei Customer Service Center.