ALM-12834 Board Temperature Abnormal Alarm

Description

This alarm is reported when the temperature of the PA board exceeds the upper threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
12834 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

107:BTS3900E

3 Board No.

Number of the fault board

0-3: BTS3900E

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

30:BTS3900E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When the alarm is generated, the PA board may be burnt out.

System Actions

None.

Possible Causes

  • The ambient temperature is too high.
  • The BTS3900E hardware is faulty.

Procedure

  1. Check the working environment of the BTS.

    Check whether the ambient temperature is higher than 50℃. If yes, improve the ambient temperature or the ventilation. Check whether the alarm is cleared after half an hour.

    Y => The alarm is cleared. End the alarm handling.

    N=> The alarm is not cleared. Go to procedure 2.

  2. Replace the BTS3900E.

    Replace the 3900E Module, and check whether the alarm is cleared.

    Y=> The alarm is cleared. End the alarm handling.

    N=> The alarm is not cleared. Contact the Huawei Customer Service Center.