ALM-12838 Site Reset Fault

Description

This alarm is reported when the base station is started or reset.

Attribute

Alarm ID Alarm Severity Alarm Type
12838 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

107:BTS3900E

3 Board No.

Number of the fault board

0-3: BTS3900E

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

30:BTS3900E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

The system automatically clears the alarm in three minutes after the alarm is generated.

Possible Causes

The base station is reset.

Procedure

  1. Query whether manual reset of the base station is performed.

    Y=> Manual reset of the base station is performed, and the alarm will be automatically cleared in three minutes. End the alarm handling.

    N=> Manual reset of the base station is not performed. Go to step 2.

  2. Check whether the base station is reset due to the BSC reset. View the OML message, and check whether the BSC is reset. Y=> The BSC is reset, and the site reset alarm will be automatically cleared in three minutes. End the alarm handling. N=> The BSC is not reset. Go to step [3].

  3. Check whether the base station is powered off.

    Check whether the base station is reset due to power-off of the base station.

    Y=> The base station is reset due to power-off. The fault may be caused by the exceptions of the power supply to the base station. End the alarm handling.

    N=> The base station is not reset due to power-off. The fault may be the hardware fault. Contact Huawei Customer Service Center .