ALM-13062 Monitoring Unit Hardware Faulty

Description

This alarm is reported when the hardware of the monitoring unit is faulty.

Attribute

Alarm ID Alarm Severity Alarm Type
13062 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

162:GMU

3 Board No.

Number of the fault board

0:GMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

1: EMU hardware faulty

2: PMU hardware faulty

3: TCU hardware faulty

4: FMU hardware faulty

5: HPMU hardware faulty

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

30:BTS3900E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

13 Problem

Problem

1: The EMU hardware is faulty.

2: The PMU hardware is faulty.

3: The TCU hardware is faulty.

4: The FMU hardware is faulty.

5: The HPMU hardware is faulty.

Impact on the System

The monitoring unit cannot work properly.

System Actions

None.

Possible Causes

The hardware of the monitoring unit is faulty.

Procedure

  1. Reset the monitoring unit.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Go to procedure 2.

  2. Replace the monitoring unit.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.


Huawei Proprietary and Confidential