ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 162:GMU |
3 | Board No. | Number of the fault board 0:GMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 1: Too high 2: Too low |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 30:BTS3900E; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
13 | Problem 1: Too high 2: Too low | Problem 1: Too high 2: Too low |
If the cabinet temperature is too high, the TRX starts overtemperature protection. Thus, the ongoing services are disrupted.
How to check the temperature threshold: Run the LST BTSEXD command on the MML client and set the parameters as required(IDTYPE=BYID, BTSID=BTS Index).
Y => The cabinet temperature is higher than the temperature upper threshold. Go to procedure 2.
N => The cabinet temperature is normal. Contact Huawei Customer Service Center.
If the air conditioner or fan is faulty, rectify the fault. Wait until the cabinet temperature is normal, and then check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to procedure 3.
Check whether the preset threshold is too low. The normal cabinet temperature ranges from 0 to 40 degrees Celsius.
Y => The preset threshold is too low. Modify the threshold.
Log in to the LMT. Right-click the target site, and then choose Site Operation > Configure Site Attributes. Click Extended Attributes in the displayed Configure Site Attributes dialog box. Then, modify the temperature upper threshold. After the modification is complete, check whether the alarm is cleared. If the alarm is cleared, no further action is required. If the alarm is not cleared, go to procedure [4].
N => The preset threshold is in the normal range. Go to procedure 4.
Check the state of the temperature sensor. Replace the temperature sensor if it is faulty. Then, check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.