ALM-13096 Battery Temperature Abnormal

Description

This alarm is reported when the temperature of batteries is too high or too low.

Attribute

Alarm ID Alarm Severity Alarm Type
13096 Minor Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

162:GMU

3 Board No.

Number of the fault board

0:GMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

1: Too high

2: Too low

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

30:BTS3900E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

13 Problem 1: Too high 2: Too low

Problem

1: Too high

2: Too low

Impact on the System

The supply of backup power to the BTS is affected. In a severe case, the batteries are disconnected because of overtemperature or undertemperature protection.

System Actions

None.

Possible Causes

  • Overload or short circuit occurs.
  • The related alarm threshold is set improperly.
  • The ambient temperature is abnormal.

Procedure

  1. Check the related battery temperature threshold at which the alarm is reported.
    1. Query the threshold settings, and check whether the threshold is properly set:

      Y => The threshold is properly set. Go to procedure 2.

      N => The threshold is improperly set. Go to step b.

    2. Change the temperature threshold that is improperly set.

      Change the threshold, and then check whether the alarm is cleared:

      Y => The alarm is cleared. No further action is required.

      N => The alarm is not cleared. Go to procedure 2.

  2. Check the heat exchanger.
    1. Check whether the heat exchanger works properly:

      Y => The heat exchanger works properly. Go to procedure 3.

      N => The heat exchanger does not work properly. Go to step b.

    2. Repair the heat exchanger.

      Repair the heat exchanger, and then check whether the alarm is cleared:

      Y => The alarm is cleared. No further action is required.

      N => The alarm is not cleared. Go to procedure 3.

  3. Replace the temperature sensor.

    Replace the temperature sensor, and then check whether the alarm is cleared:

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.