ALM-13100 Abnormal Temperature at the Air Inlet of the Cabinet

Description

This alarm is reported when the temperature at the air inlet of the cabinet is too high or too low.

Attribute

Alarm ID Alarm Severity Alarm Type
13100 Minor Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

162:GMU

3 Board No.

Number of the fault board

0:GMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

1: Too high

2: Too low

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

30:BTS3900E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

13 Problem 1: Too high 2: Too low

Problem

1: Too high

2: Too low

Impact on the System

The fans rotate at their full speed and thus generate uncomfortable noise. The intelligent temperature control fails.

System Actions

None.

Possible Causes

  • The ambient temperature is too high or too low.
  • The alarm threshold is inappropriate.
  • The sensor is faulty.

Procedure

  1. Read from the BSC the temperature at the air inlet of the fan monitoring board.
    1. Read the temperature reported to the BSC.
    2. Check whether the temperature reported is the same as the actual temperature of the cabinet.

      Y => The temperature reported is the same as the actual temperature. Go to procedure 2.

      N => The temperature reported is different from the actual temperature. Go to procedure 4.

  2. Check the alarm threshold.
    1. Compare the temperature reported with the alarm threshold. (By default, the high-temperature threshold is 80 degrees Celsius and the low-temperature threshold is -20 degrees Celsius.)
    2. Determine whether the temperature reported is within the range from the low-temperature threshold to the high-temperature threshold:

      Y => The temperature is normal. No further action is required.

      N => Go to procedure 3.

  3. Reset the fan monitoring board.
    1. Reset the fan monitoring board remotely by software.
    2. Check whether the alarm is cleared:

      Y => The alarm is cleared. No further action is required.

      N => The alarm is not cleared. Go to procedure 4.

  4. Replace the fan monitoring board, and then check whether the alarm is cleared:

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.