ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Subrack No. |
2 | Slot No. | Slot No. |
3 | Cpu No. | CPU No. |
4 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
If this alarm is reported from all the clock references being configured on the interface boards, the voice quality and the reliable transmission of the data service might be affected.
Y => The alarm occurs to both GSCUs. Go to 2.
N => The alarm occurs to only one board. Go to 8.
Y => The clock is incorrectly configured. Go to 3.
N => The clock is correctly configured. Go to 4.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm persists. Go to 4.
Y => An alarms occurs. Go to 5.
N => No alarm occurs. Please contact Huawei Customer Service Center.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm persists. Go to 6.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm persists. Go to 7.
Y => The alarm is cleared. Replace the standby interface board. The alarm handling is complete.
N => The alarm persists. Please contact Huawei Customer Service Center.
Y => The alarm occurs to the active GSCU. Go to 9.
N => The alarm occurs to the standby GSCU. Go to 10.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm persists. Go to 10.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm persists. Please contact Huawei Customer Service Center.