20114 Inter-Board HIG Link Faulty

Description

HiGig link between boards is disconnected.

Attribute

Alarm ID Alarm Severity Alarm Type
20114 Major Fault

Parameters

ID Name Meaning
1 Subrack No.

Subrack No.

2 Slot No.

Slot No.

3 Cpu No.

CPU No.

4 HIG Link No.

The disconnected inter-board HiGig link No.

5 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

  • If only one or two HIGs fail, the service between the active and standby GSCUs decreases.
  • If three HIGs fail, the standby GSCU is unavailable for service, and the switch capability of the system decreases.

System Actions

The service carried by the faulty HIG is passed to other normal HIGs.

Possible Causes

  • The peer board is reset.
  • The local or peer board is not securely installed.
  • The local board is faulty.
  • The local board is faulty.
  • The backplane (including slots and circuit) is faulty.

Procedure

  1. Check whether the peer board is reset.

    Y => The peer board is reset. This alarm is caused by the restoration of the peer board. The alarm handling is complete.

    N => The peer board is not reset. Go to 2.

  2. Secure the installation of the two GSCUs, and then check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Go to 3.

  3. Reset the standby board and wait until the board is successfully restarted. Check whether the alarm is cleared after the standby board restarts.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Go to 4.

  4. Replace the local board and wait until the new board is successfully restarted. Check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Go to 5.

  5. Switch the active board into standby state and wait until the standby board is successfully restarted. Check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Go to 6.

  6. Replace the new standby board and wait until the new board is successfully restarted. Check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Please contact Huawei Customer Service Center.