20234 Trace Flag Mismatch on the High-Order Path of the Optical Port (HPTIM)

Description

The higher order path trace byte J1 is mismatched. Byte J1 is used to repeatedly send the identifier of higher order path access point, so the receiving end can confirm the continuous connection to the transmitting end.

Attribute

Alarm ID Alarm Severity Alarm Type
20234 Major Fault

Parameters

ID Name Meaning
1 Subrack No.

Subrack No.

2 Slot No.

Slot No.

3 Cpu No.

CPU No.

4 Optical Interface No.

Optical interface No.

5 High Order Path No.

High Order Path No.

6 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

None.

System Actions

None.

Possible Causes

The J1 byte received at the local end is inconsistent with what is expected.

Procedure

  1. Set the J1 byte at the local end to the same value with that transmitted from the peer board. Check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Please contact Huawei Customer Service Center.