ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Subrack No. |
2 | Slot No. | Slot No. |
3 | Cpu No. | CPU No. |
4 | Tributary Unit No. | 0 - 62(for E1 mode), 0 - 83(for T1 mode). |
5 | Loopback Type | 0=No Loop,3=Lower Order Path Line Loop,4=Tributary Line Loop,5=Tributary System Loop |
6 | Site No. | The IDs of all sites whose OMLs are on the faulty E1/T1. If BTS are cascade connected,a maximum of 4 sites are shown.Only Abis E1/T1 alarm has this parameter. |
7 | Site Name | The Names of all sites whose OMLs are on the faulty E1/T1. If BTS are cascade connected,a maximum of 4 sites are shown.Only Abis E1/T1 alarm has this parameter. |
8 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
The local tributary is randomly set as one of the loopback mode of the the Optical Port.
Y => No handling is required.
N => Go to 2.
Y => The alarm is cleared. The alarm handling is complete.
N => Please contact Huawei Customer Service Center.