20272 Monitor Board Out of Position

Description

Monitoring boards (power distribution box, fan box, and EAC) are not connected to the BSC.

Attribute

Alarm ID Alarm Severity Alarm Type
20272 Major Fault

Parameters

ID Name Meaning
1 Subrack No.

Subrack No.

2 Monitor Board

Monitor Board

3 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

  • If one port is faulty, the service quality between the GSCU and the service boards decreases.
  • If two ports are faulty, the service between the GSCU and the service boards is interrupted.

System Actions

None.

Possible Causes

  • The monitor board being examined is not connected to the subrack with the serial port cable.
  • The serial cable that connects the board and the subrack is faulty.
  • The board being checked is faulty.
  • The GSCU is faulty.
  • The backplane is faulty.

Procedure

  1. Check whether a correlated parent alarm occurs.

    Y=> Clear the parent alarm according to the corresponding handling suggestions. Check whether the alarm is cleared.

    N=> Go to 2.

    Correlated parent alarm

    20271 Serial Port Fault

    The parent alarm and the child alarm have the same Subrack No. and Slot No. in the alarm location information.

  2. Check whether the monitor board is connected to the subrack with the serial port cable.

    Y => Go to 4.

    N => Go to 3.

  3. Connect the monitor board and the subrack with the serial port, and then check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Go to 4.

  4. Reconnect the serial port cable that connects the monitor board and the subrack, and then check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Go to 5.

  5. Replace the serial port cable that connects the monitor board and the subrack, and then check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Go to 6.

  6. Replace the monitor equipment, and then check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Go to 7.

  7. Switch the GSCU, and then check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Please contact Huawei Customer Service Center.