20322 Unavailable Current Clock Reference for GGCU

Description

The current clock reference of GGCU board is in unusable state.

Attribute

Alarm ID Alarm Severity Alarm Type
20322 Minor Fault

Parameters

ID Name Meaning
1 Subrack No.

Subrack No.

2 Slot No.

Slot No.

3 Cpu No.

CPU No.

4 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

None.

System Actions

The phase-lock loop of the GGCU enters self-oscillation state or remains unchanged.

Possible Causes

  • The input signal for the clock reference is lost.
  • The frequency offset for the input signal of the reference source is abnormal, that is, the frequency offset is greater than that being introduced.
  • The board is faulty.

Procedure

  1. As the handling procedures vary for different clock reference, please specify the type of the clock reference in advance by the values of parameter 4. If the type of the faulty clock reference is 2 MHz or 2 MBPS:
    1. Check whether a correlated parent alarm occurs.

      Y=> Clear the parent alarm according to the corresponding handling suggestions. Check whether the alarm is cleared.

      N=> Go to b.

      Correlated parent alarm

      20321 Unavailable Clock Reference for GGCU

      The parent alarm and the child alarm have the same Subrack No. and Slot No. in the alarm location information.

      The clock source corresponding to Source index No. in the alarm location information of the parent alarm must be the current clock source of the GGCU.

    2. Secure the clock cable of the GGCU that connects the clock reference, and then check whether the alarm is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm persists. Go to c.

    3. Replace the clock cable, and then check whether the alarm is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm persists. Go to d.

    4. Check whether the frequency offset output from the clock source is normal by using relevant equipment.

      Y => The frequency offset is normal. Go to e.

      N => The frequency offset is abnormal. Go to f.

    5. Replace the board, and then check whether the alarm is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm persists. Please contact Huawei Customer Service Center.

    6. Check whether the clock source is of BITS clock.

      Y => Contact the the maintenance engineer concerning the BITS clock to solve the problem. The alarm handling is complete.

      N => The clock source is from the interface board of the BSC. Go to step g.

    7. The interface board that output the clock source is faulty. Clear the relevant fault ,and then check whether the alarm is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm persists. Please contact Huawei Customer Service Center.

  2. As the handling procedures vary for different clock reference, please specify the type of the clock reference in advance by the values of parameter 4. If the type of the faulty clock reference is 8K:
    1. Check whether a correlated parent alarm occurs.

      Y=> Clear the parent alarm according to the corresponding handling suggestions. Check whether the alarm is cleared.

      N=> Go to b.

      Correlated parent alarm

      20321 Unavailable Clock Reference for GGCU

      The parent alarm and the child alarm have the same Subrack No. and Slot No. in the alarm location information.

      The clock source corresponding to Source index No. in the alarm location information of the parent alarm must be the current clock source of the GGCU.

    2. Secure the GGCU and the interface board that output the clock source, and then check whether the alarm is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm persists. Go to c.

    3. Check whether there are clock-related alarms with the interface board that output the clock source.

      Y => There are clock-related alarms. Go to d.

      N => There is no clock-related alarm. Go to e.

    4. Clear the clock alarm of the interface board according to its relevant handling suggestions, and then check whether the alarm of the board is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm persists. Go to e

    5. Replace the faulty GGCU, and then check whether the alarm is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm persists. Please contact Huawei Customer Service Center.