20361 TDM panel Link Failure of GTNU

Description

Faulty TDM link on the GTNU Panel

Attribute

Alarm ID Alarm Severity Alarm Type
20361 Minor Fault

Parameters

ID Name Meaning
1 Subrack No.

Subrack No.

2 Slot No.

Slot No.

3 Cpu No.

CPU No.

4 Panel Link No.

Panel Port No.

5 Fault Type

Fault type

6 Panel Port No.

Number of the panel port that carries the link (A GTNU panel has six ports and each port has two port numbers. The six ports are numbered 0 - 11.)

7 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

Some inter-subrack calls may fail.

System Actions

None.

Possible Causes

  • The peer board that carries the faulty link is reset.
  • The clock signals transmitted to the service board from the GSCU are faulty.
  • The cable between the GTNU panels are not securely inserted.
  • The cable between the GTNU panels is faulty.
  • The local board is faulty.
  • The peer board that carries the faulty link is faulty.

Procedure

  1. Check whether a correlated parent alarm is reported.

    Y=> Clear the parent alarm according to the handling suggestions. Check whether the alarm is cleared .

    N => Go to 2.

    Correlated parent alarm

    20016 Faulty 32 MHz Clock from the Backplane

    The parent alarm and the child alarm have the same Subrack No. and Slot No. in the alarm location information.

  2. Check whether the peer board is reset.

    Y => The peer board is reset. This indicates that the alarm is caused by the reset of the peer board. The alarm handling is complete.

    N => The peer board is not reset. Go to 3.

  3. Check whether an alarm related to the clock is generated on the active GSCU.

    Y => Go to 4.

    N => Go to 5.

  4. Clear the clock alarm on the GSCU according to the handling suggestions, and then check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to 5.

  5. Secure the cable between the local board and the peer board, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to 6.

  6. Replace the cable between the local board and the peer board, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to 7.

  7. Replace the faulty board and wait until the new board is successfully loaded and reset. Then, check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to 8.

  8. Replace the peer board that carries the faulty link and wait until the new board is successfully loaded and reset. Then, check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Please contact Huawei Customer Service Center.