20951 Status Change Event Alarm

Description

The board status changes from active status to standby status or from standby status to active status.

Attribute

Alarm ID Alarm Severity Alarm Type
20951 Minor Event

Parameters

ID Name Meaning
1 Subrack No.

Subrack No.

2 Slot No.

Slot No.

3 Cpu No.

CPU No.

4 Active/Standby State After The Change

0=Active,1=Standby

5 Active/Standby State Before The Change

0=Active,1=Standby

6 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

The switchover between the active and standby boards is performed. There is no impact on the service.

System Actions

The board that is switched over from the active state to the standby state is reset.

Possible Causes

  • The board is manually switched over through the LMT.
  • The active board before the switchover is reset or pulled out.
  • The active board before the switchover is faulty.

Procedure

  1. None.