ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Number of the subrack where the board is inconsistent with its configuration |
2 | Slot No. | Number of the slot where the board is inconsistent with its configuration |
3 | CPU No. | Number of the CPU where the board type is inconsistent with its configuration. |
4 | Physical Type | 1=SCU,2=GCU,3=EIU/OIU,4=TNU,5=XPU,6=DPU,7=FG2/GOU/PEU |
5 | Configured Type | 1=SCU,2=GCU,3=EIU/OIU,4=TNU,5=XPU,6=DPU,7=FG2/GOU/PEU |
6 | Checking result | 1=Loading allowed,3=Loading not allowed |
7 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
8 | Cause Code | 1=Inconsistent Sub-Board Alarm,2=Board Physical Type inconsistent |
Check whether the configuration of the sub-board in the system is consistent with that being installed in the subrack.
Y => Replace the sub-board in the subrack or clear the configuration of the board and then reconfigure with the correct board in the LMT. The alarm handling is complete.
N => Please contact Huawei Customer Service Center.
Y =>Please contact Huawei Customer Service Center.
N =>Go to b.
Y =>Please contact Huawei Customer Service Center.
N =>The alarm handling complete.