21025 Patch not confirm

Description

GBAM/GOMU Patch is not confirmed

Attribute

Alarm ID Alarm Severity Alarm Type
21025 Major Fault

Parameters

ID Name Meaning
1 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

The unconfirmed patch might cause the abnormality of the system.

System Actions

None.

Possible Causes

The current patch of the OMU is not confirmed.

Procedure

  1. Run the MML command LST PATCH to check the patch is confirmed or not.

    Y =>Please contact Huawei Customer Service Center;

    N =>Run the MML command CON PATCH to confirm the patch.The alarm handling is complete.