ALM-2122 TRX Power Decrease Alarm

Description

There is a restriction to the static power when a TRX works together with a PBU and CDU. When the TRX static power exceeds this restriction, the TMU will command the TRX to lower its static power to a reasonable range and report this alarm.

Attribute

Alarm ID Alarm Severity Alarm Type
2122 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:TRX

3 Board No.

Number of the fault board

0:TRX 0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

3: BTS30

5: BTS312

10: BTS3012A

11: BTS3006A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The static power of the TRX will be reduced upon occurrence of this alarm. This might affect the coverage area.

System Actions

None.

Possible Causes

  • Data configuration error.
  • The power of the ECDU is too low.

Procedure

  1. A TRX that works with a PBU must use an ECDU. Locally check the CDU type. If it is a common CDU, replace it with an ECDU. Then check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Huawei Customer Service Center.