21251 Daemon Version Not Match Alarm

Description

Inconsistent Daemon Version.

Attribute

Alarm ID Alarm Severity Alarm Type
21251 Major Fault

Parameters

ID Name Meaning
1 Subrack No.

Number of the subrack where the alarm is generated

2 Slot No.

Number of the slot where the alarm is generated

3 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

The backup function is not available.

System Actions

None.

Possible Causes

  • The Daemon is being upgraded.
  • The versions of Daemon running on the two boards are not consistent.

Procedure

  1. Upgrade the Daemon with an early version.

  2. Replace the boards with those with the same version.