21255 Abnormal OMU Data Configuration

Description

The actual OMU type (External, Front, and Back), OMU subrack number, or OMU slot number is inconsistent with those specified by the OMU data configuration.

Attribute

Alarm ID Alarm Severity Alarm Type
21255 Major Fault

Parameters

ID Name Meaning
1 Subrack No.

Number of the subrack where the alarm is generated

2 Slot No.

Number of the slot where the alarm is generated

3 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

  • The OMU software may fail to be started.
  • The number of GOMUs is one in the data configuration file, that is, the single-GOMU system. If the OMU software is stopped, the external IP address may be released. In this case, if the physical IP is unavailable, the BSC cannot be remotely operated.
  • The number of GOMUs is two in the data configuration file, that is, the dual-GOMU system. If the software of the active GOMU is stopped, the external IP address may not be released. In this case, the IP address of the active OMU conflicts with that of the standby GOMU. Then, the BSC cannot be remotely operated.

System Actions

None.

Possible Causes

The actual OMU type (External, Front, and Back), OMU subrack number, and OMU slot number is inconsistent with those specified by the OMU data configuration.

Procedure

  1. Ensure that the actual OMU type (External, Front, and Back), OMU subrack number, or OMU slot number is consistent with those specified by the OMU data configuration.

    Y => Contact Huawei Customer Service Center.

    N => Change the OMU data configuration and reset the OMU core process. Go to 2.

  2. Check whether the alarm is cleared.

    Y => The alarm handling is complete.

    N => Contact Huawei Customer Service Center.