ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Number of the subrack where the alarm is generated |
2 | Slot No. | Number of the slot where the alarm is generated |
3 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
The actual OMU type (External, Front, and Back), OMU subrack number, and OMU slot number is inconsistent with those specified by the OMU data configuration.
Y => Contact Huawei Customer Service Center.
N => Change the OMU data configuration and reset the OMU core process. Go to 2.
Y => The alarm handling is complete.