21256 GOMU Disk Fault Alarm

Description

GOMU Disk Fault Alarm.

Attribute

Alarm ID Alarm Severity Alarm Type
21256 Minor Fault

Parameters

ID Name Meaning
1 Subrack No.

Number of the subrack where the alarm is generated

2 Slot No.

Number of the slot where the alarm is generated

3 RaidID

Raid ID where the alarm is generated

4 Cause

0=Normal,1=Degraded,2=Failed,3=Missing,4=Need To Rebuild,5=Resync,6=Initializing,255=Unknown

5 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

A potential risk for the normal operation of the system exists.

System Actions

None.

Possible Causes

The raid of OMU disk is fault.

Procedure


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.