ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Number of the subrack where the alarm is generated |
2 | Slot No. | Number of the slot where the alarm is generated |
3 | Sub Slot No. | Number of the sub slot where the alarm is generated |
4 | Optical Port No. | Number of the optical port where the alarm is generated |
5 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
The protection modes at two ends of the APS protection section are different: one end is 1:1 protection mode and the other end is 1+1 protection mode.
Y => Contact Huawei Customer Service Center.
N => Configure the APS protection mode at two ends to be the same. Interconnect the two ends, and then Go to 2.
Y => The alarm handling is complete.
N => Contact Huawei Customer Service Center.