ALM-2166 TRX Clock Prompt Alarm

Description

A TRX reports this alarm when detecting that main clock signal or the slave clock signal input to it is not available.

Attribute

Alarm ID Alarm Severity Alarm Type
2166 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:TRX

3 Board No.

Number of the fault board

Value range: 0-71

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:Main clock alarm

1:Slave clock alarm

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

3: BTS30

5: BTS312

10: BTS3012A

11: BTS3006A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The services will be interrupted when Sub No.0 and Sub No.1 are generated at the same time.

System Actions

None.

Possible Causes

The main clock signal or the slave clock signal input to the TRX is not available.

Procedure

  1. Replace the TMU

    Replace the TMU and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 2.

  2. Replace the TDU

    Replace the TDU and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Huawei Customer Service Center.