ALM-2206 Board Type Mismatch Alarm

Description

The alarm is triggered when the type of a board actually installed in a slot of the rack is different from that of the board configured in the same slot at the BSC side.

Attribute

Alarm ID Alarm Severity Alarm Type
2206 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:TRX

3 Board No.

Number of the fault board

0:TRX 0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:indicates that the type of the actually installed board is PBU.

0:indicates that the type of the actually installed board is PBU.

1:indicates that the type of the actually installed board is P-TRX.

2:indicates that the type of the actually installed board is DTRX or DETR

3:indicates that the type of the actually installed board is RTRX or RETR

4:indicates that the type of the actually installed board is R-TRX.

6:indicates that the type of the actually installed board is PETR.

7:indicates that the type of the actually installed board is EETR.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

3: BTS30

5: BTS312

10: BTS3012A

11: BTS3006A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The board actually installed in the corresponding slot cannot work normally upon occurrence of this alarm.

System Actions

None.

Possible Causes

The type of a board actually installed in a slot of the rack is different from that of the board configured in the slot at the BSC side.

Procedure

  1. Replace the installed board based on the data configuration or modify the data configured at the BSC side. Check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Huawei Customer Service Center.