ALM-2210 E1 Remote Loop Test Alarm

Description

The alarm is triggered when an E1 loopback test command is sent to the BTS through the BSC maintenance system.

Attribute

Alarm ID Alarm Severity Alarm Type
2210 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:TMU

3 Board No.

Number of the fault board

0:TMU 0

1:TMU 1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

3: BTS30

5: BTS312

10: BTS3012A

11: BTS3006A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The BTS cannot communicate with the BSC and the BTS services are interrupted upon occurrence of this alarm.

System Actions

None.

Possible Causes

E1 loopback test.

Procedure

  1. This alarm is a warning reported upon manual remote loopback test. No manual handling is required for it.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.