ALM-2214 E1 Local Alarm

Description

The alarm is triggered when the BTS transmission is interrupted because it has not received correct E1 signals.

Attribute

Alarm ID Alarm Severity Alarm Type
2214 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:TMU

3 Board No.

Number of the fault board

0:TMU 0

1:TMU 1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0~23:The transmission between 0-23 of the E1 port and the upper-level BSC or BTS is abnormal.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

3: BTS30

5: BTS312

10: BTS3012A

11: BTS3006A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The services of the near-end BTS are interrupted because it cannot communicate with the upper level BSC or BTS.

System Actions

None.

Possible Causes

  • The transmission link is not available.
  • The settings for the DIP switches of the BTS are not correct.
  • The TMU is faulty.

Procedure

  1. Check the DIP switches settings of the BTS

    Check whether the DIP switches S1, S2, S10 and S11 on the TMU panel are correctly set. If no, modify the settings based on the following descriptions:

    S1: ON indicates that the impedance over E1 ports 3 and 4 is 75 ohm ; OFF indicates the impedance over the two ports is 120 ohm.

    S2: ON indicates that the impedance over E1 ports 1 and 2 is 75 ohm; OFF indicates the impedance over the two ports is 120 ohm.

    S10: ON indicates that the outer conductor of E1 links 1 and 2 is grounded while OFF indicates that the outer conductor is not.

    S11: ON indicates that the outer conductor of E1 links 3 and 4 is grounded while OFF indicates that the outer conductor is not.

    Check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 2.

  2. Check the transmission link of the near-end BTS
    1. Perform a loopback test by connecting port RX0 with TX0 on the near-end BTS. Check whether the indicator LIU0 on the TMU panel is off.

      Y=> Go to Step b.

      N=> Go to Step 4.

    2. Restore the connection to the appearance before the loopback test. Check whether the alarm is cleared.

      Y=> The alarm handling ends.

      N=> Go to Step 3.

  3. Check the peer transmission link

    Perform a loopback test on the transmission link at the upper level BSC or BTS. Check whether the indicator LIU corresponding to the peer E1 link is off.

    Y=> The alarm may be caused by hardware failure. Contact Huawei Customer Service Center.

    N=> The peer transmission link is not available. Repair the peer transmission link and the alarm handling ends.

  4. Replace the TMU

    Replace the TMU and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Huawei Customer Service Center.