ALM-2270 Site Reset Alarm

Description

The alarm is triggered when the BTS starts up.

Attribute

Alarm ID Alarm Severity Alarm Type
2270 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:TMU

3 Board No.

Number of the fault board

0:TMU 0

1:TMU 1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

3: BTS30

5: BTS312

10: BTS3012A

11: BTS3006A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

BTS resetting.

Procedure

  1. Check whether the BTS has been manually reset

    Check whether the BTS has been manually reset

    Y=> The alarm will automatically be cleared in three minutes. The alarm handling ends.

    N=> Go to Step 2.

  2. Check whether the BSC has been reset

    Check whether the BSC has been reset.

    Y=> The alarm will automatically be cleared in three minutes. The alarm handling ends.

    N=> Go to Step 3.

  3. Check whether the BTS is powered down

    Check whether the BTS is powered down

    Y=> The power supply to the BTS might be abnormal. Resume supplying power to the BTS and the alarm handling ends.

    N=> The alarm may be caused by hardware failure. Huawei Customer Service Center.