ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 130:CDU |
3 | Board No. | Number of the fault board 0:CDU 0 1:CDU 1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 3: BTS30 5: BTS312 10: BTS3012A 11: BTS3006A |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Turn off the power amplifier of the TRX corresponding to the CDU. Check whether the jumpers between the CDU antenna port and the feeders are securely connected.
Turn off the power amplifier of the TRX corresponding to the CDU to stop power transmission before disconnecting the jumpers between the CDU output port and the TRX input port.
Y=> Go to Step 2.
N=> Secure the jumper connectors to the ports. Go to Step 3.
Measure the VSWR of the jumper side at the CDU antenna port using a sitemaster or another meter with the similar function. Check whether the measured VSWR exceeds the relevant alarm threshold.
Y=> Further measure the VSWR of the antenna feeder tributary, including the jumpers, lightning arrester, feeder and antenna.
N=> There might be a false alarm. Replace the CDU and go to Step [3].
Secure the jumper connectors to the CDU output port and the TRX input port. Turn on the power amplifier of the TRX. Check whether the alarm is cleared.
Y=> The alarm handling ends.
N=> Huawei Customer Service Center.
Note:
Handle this alarm upon occurrence of it because it will cause the BTS to turn off the power amplifier to stop power output.