ALM-2548 TCU Temperature Sensor Alarm

Description

This alarm is triggered when any of the three temperature sensors of the TCU is damaged.

Attribute

Alarm ID Alarm Severity Alarm Type
2548 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

139:TCU

3 Board No.

Number of the fault board

0:TCU 0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

10: BTS3012A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

Any of the three temperature sensors of the TCU fails.

Procedure

  1. Check all the temperature sensors in order.

    If all the temperature sensors work normally, go to Step [2].

    If any temperature sensor is abnormal, replace it. See whether the alarm is cleared.

    Y=> The alarm is cleared. Alarm handling is complete.

    N=> The alarm is not cleared. Go to Step 2.

  2. Replace the TCU

    Replace the TCU and view whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Please contact Huawei Customer Service Center.

    Follow the following instructions to replace the TCU:

    1. Shut off the power supply for voltage regulator of the air-conditioner.
    2. Shut off the power supply for the TCU.
    3. Unclench the screws fastening the TCU, then remove the TCU and place it on the anti-static foam block.
    4. Insert a new TCU and fasten it with screws.
    5. Start the power supply for voltage regulator of the air-conditioner.
    6. Enable the power supply for the TCU.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.