ALM-2576 PBU Slave Clock Alarm

Description

This alarm is triggered when the PBU slave clock system cannot detects clock signals in a time (shorter than one second).

Attribute

Alarm ID Alarm Severity Alarm Type
2576 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

147:PBU

3 Board No.

Number of the fault board

0:PBU 0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

3: BTS30

5: BTS312

10: BTS3012A

11: BTS3006A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

This alarm indicates that the master clock of the PBU fails. In this case, the system starts the standby clock system if any, thus having no impact upon the services.

System Actions

The system starts the standby clock system if any.

Possible Causes

  • The TMU clock system fails.
  • The clock transmission cable is faulty.
  • The TDU is faulty.

Procedure

  1. Check whether the extended TMU has been installed.

    Check whether the extended TMU has been installed.

    Y=> Go to Step 2.

    N=> No handling is required.

  2. Replace the extended TMU.

    Replace the extended TMU and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 3.

  3. Replace the TDU

    Replace the TDU and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 4.

  4. Replace the whole set of distribution cables of the rack

    Replace the whole set of distribution cables of the rack. View whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.