ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 135:MFU |
3 | Board No. | Number of the fault board 0:MFU 0 1:MFU 1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 7: BTS3001C-108/BTS3001C-116 8: BTS3001C-204 |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
When this alarm occurs, all the services on the current BTS3001C are interrupted.
Check whether the BTS3001C software version is correct.
Y=> Go to Step 3.
N=> Go to Step 2.
Load and activate the correct software version. Check whether the alarm is cleared.
Y=>The alarm handling ends.
N=>Go to step 3.
In the LMT, perform fourth-level reset on the BTS3001C and then check whether the alarm is cleared.
Y=>The alarm handling ends.
N=>The possible cause is that the hardware in the BTS3001C is faulty. Contact Huawei Customer Service Center.