ALM-3148 E1 Remote Loop Test alarm

Description

This alarm is triggered when the command to start the E1 loop test is delivered to the BTS3001C through the maintenance system.

Attribute

Alarm ID Alarm Severity Alarm Type
3148 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:MMU

3 Board No.

Number of the fault board

0:MMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

7: BTS3001C-108/BTS3001C-116

8: BTS3001C-204

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When this alarm occurs, both the communications between the BTS3001C and the BSC and the services in the BTS3001C will be interrupted.

System Actions

When the test time is up, the BTS3001C is reset automatically and resumes to normal operation.

Possible Causes

The cause is the E1 loop test.

Procedure

  1. The system reports this warning when the E1 loop test is started manually. It is not necessary to handle it.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.