ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 129:MMU |
3 | Board No. | Number of the fault board 0:MMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 7: BTS3001C-108/BTS3001C-116 8: BTS3001C-204 |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
When this alarm occurs, the services in the BTS3001C are normal but the system cannot detect alarms from the ASU.
Check whether the BTS3001C transmission service status is normal.
Y=>The ASU host software is faulty or lost. Go to step 3.
N=>Go to step 2.
Log on to an NE through the command line software. Check whether the host software exists and whether it is working normally.
Method to check whether the host software exists: After logon through the command line software. If the prompt interface "NEBIOS is running. Download NESOFT please!" appears, the host software does not exist. Otherwise, the host software is not lost.
Y=>Go to step 4.
N=>Go to step 3.
Load ASU host software,and check whether the original alarm has been cleared.
Method to Load ASU host software : Run Run OptiX Navigator.exe. Click [File/New Download Window] and the corresponding interface will appear. Set the downloading NE ID and downloading file path. Reload the ASU host software and reset the ASU.
Y=>The alarm handling ends.
N=>The possible cause is that the hardware in the BTS3001C is faulty.Please contact Huawei Customer Service Center.
Reset the ASU and then check whether the alarm has been cleared.
Y=>The alarm handling ends.
N=>The possible cause is that the hardware in the BTS3001C is faulty. Please contact Huawei Customer Service Center.