ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 129:MMU |
3 | Board No. | Number of the fault board 0:MMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0:The alarm is reported by MFU0. 1:The alarm is reported by MFU1. |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 7: BTS3001C-108/BTS3001C-116 8: BTS3001C-204 |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
If this alarm occurs, the BTS3001C power supply is abnormal. If the abnormal power supply last for a long time, it may damage the BTS.
Check the BTS3001C power supply. If the fluctuation of the power supply network causes the alarm, use a mains voltage stabilizer or UPS to prevent damages to the BTS3001C. After the voltage has been stabilized, check whether the alarm has been cleared.
Y=>The alarm handling ends.
N=>The possible cause is that the hardware in the BTS3001C is faulty.Please contact Huawei Customer Service Center.