ALM-3200 BTS3001C Power Abnormal alarm

Description

This alarm is triggered when the voltage of the BTS3001C input power supply is higher than 290V AC or lower than 150V AC.

Attribute

Alarm ID Alarm Severity Alarm Type
3200 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:MMU

3 Board No.

Number of the fault board

0:MMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:The alarm is reported by MFU0.

1:The alarm is reported by MFU1.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

7: BTS3001C-108/BTS3001C-116

8: BTS3001C-204

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

If this alarm occurs, the BTS3001C power supply is abnormal. If the abnormal power supply last for a long time, it may damage the BTS.

System Actions

None.

Possible Causes

The BTS3001C input power supply is over or under voltage.

Procedure

  1. Check the BTS3001C power supply. If the fluctuation of the power supply network causes the alarm, use a mains voltage stabilizer or UPS to prevent damages to the BTS3001C. After the voltage has been stabilized, check whether the alarm has been cleared.

    Y=>The alarm handling ends.

    N=>The possible cause is that the hardware in the BTS3001C is faulty.Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.