ID | Name | Meaning |
---|---|---|
1 | NSEI | ID of the NSE where the alarm is generated |
2 | NSVLI | ID of the NSVL where the alarm is generated |
3 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
Y => Go to 2.
N => Reconfigure the NSE and the NSVC of the BSC to ensure that they are consistent with those of the SGSN.
N => Remove and reinsert or replace the GFGUG until the board works normally.
Y => Go to 4.
N => Reconnect the network.
Y=> The alarm handling is complete.