ID | Name | Meaning |
---|---|---|
1 | NSEI | ID of the NSE where the alarm is generated |
2 | Cause | 0=Unknow cause, 1=SIZING:Send SNS-SIZE PDU failed, 2=SIZING:Wait for SNS-ACK timeout, 3=SIZING:"Invalid number of NS-VCs", 4=SIZING:"Invalid number of IP4 Endpoints", 5=SIZING:"Invalid number of IP6 Endpoints", 6=CONFIGING:Send SNS-CONFIG PDU failed, 7=CONFIGING:Wait for CONFIG-ACK timeout, 8=CONFIGING:"Invalid number of IP4 Endpoints", 9=CONFIGING:"Invalid number of IP6 Endpoints", 10=CONFIGING:"Invalid weights", 11=CONFIGING:Wait for Remote NSVL information timeout |
3 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
Y => Go to 2;
N => Connect BSC and SGSN again.
Y => Go to 3;
Y => The alarm is cleared.