ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 82:MCI |
3 | Board No. | Number of the fault board 0:MCI0 1:MCI1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 7: BTS3001C-108/BTS3001C-116 8: BTS3001C-204 |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
When this alarm occurs, subscribers within the area covered by the BTS3001C cannot make calls.
Check whether there is a ALM-3142 MFU Communication alarm on the alarm system.
Y=>The ALM-3142 MFU Communication alarm is displayed on the alarm system. Go to Step 3.
N=>The ALM-3142 MFU Communication alarm is not displayed on the alarm system. Go to Step 2.
The Cell Attributes tab page is displayed.
The Browse FH Attributes dialog box is displayed.
If the FH Mode is set as RF FH, and there is only one frequency displayed in the MA Frequencies Assigned of the Config MA Group, then this kind of configuration may lead to downlink alarm to the non-main BCCH TRX.
Y=> The data configuration is correct. Go to Step 3.
N=>The data configuration is incorrect. Change the FH Mode to No FH. Go to Step 3.
Perform fourth-level reset on the BTS3001C through the LMT. Check whether the alarm is cleared.
Y=> The alarm handling ends.
N=> The inner container hardware may be faulty.Please contact Huawei Customer Service Center.