ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 135:DRU |
3 | Board No. | Number of the fault board 0:DRU0 1:DRU1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 9: BTS3002C |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
All services supported by the carrier are interrupted upon occurence of this alarm.
Check whether ALM-3672 E1 Local alarm is reported on the LMT.
Y=>Handle the ALM-3672 E1 Local alarm according to the corresponding handling suggestions to check whether the alarm is cleared .The alarm is cleared, Alarm handling is completed. The alarm is not cleared, Go to Step 2.
N=>Go to Step 2.
Loopback transmission: If the BTS3001C adopts E1 transmission mode, then perform loopback test for the E1 cable from the BSC or the senior BTS. If the BTS3001C adopts optical transmission mode, perform loopback test for the optical fiber from the BSC or the senior BTS and test the timeslot corresponding to the LAPD to see whether there are any error codes.
Y=> There is a fault on the peer transmission line. Repair the transmission line. The alarm handling ends.
N=>Go to Step 3.
The operation procedure is as follows:
The Configure TRX Property Wizard is displayed.
The Configure TRX Property dialog box is displayed.
Perform fourth-level reset on the BTS3002C through the LMT. Check whether the alarm is cleared.
Y=> The alarm handling ends.
N=> Go to Step 5.
Power down the BTS3002C. Remove and reinsert the modules on the backplane to ensure they are in well connection. Power on the BTS3002C and check whether the alarm is cleared.
Y=> The alarm handling ends.
N=> Go to Step 6.
Y=>The alarm is cleared. Alarm handling is completed.
N=>The alarm is not cleared. Please contact Huawei Customer Service Center.