ALM-3606 DRU Hardware alarm

Description

This alarm is triggered when the DRU RF circuit works abnormally (the output power is too large or too small), or the Flash Memory in the DRU fails.

Attribute

Alarm ID Alarm Severity Alarm Type
3606 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:DRU

3 Board No.

Number of the fault board

0:DRU0

1:DRU1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The DRU fails and run abnormally upon occurence of this alarm. As a result, all services supported by this DRU are interrupted.

System Actions

The system shuts off the power amplifier upon the detection of the alarm at the first time, then starts the power amplifier again ten minutes later. Check whether the alarm still exists. If the alarm is cleared, the alarm handling ends. If the alarm occurs again, the system shuts off the power amplifier again. The system stops the self-action if the alarm still exists after having shut off and started the power amplifier for three times.

Possible Causes

  • The RF working voltage output by the MCU is abnormal.
  • The DRU hardware is faulty.
  • The MCU hardware is faulty.

Procedure

  1. Reset the BTS

    Perform fourth-level reset on the BTS3002C or reset it by power-down (recommended) through the LMT or local maintenance system. Check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 2.

  2. Remove and reinsert the MCU and DRU

    Power down the BTS3002C. Remove and reinsert the modules on the backplane to ensure they are in well connection. Power up the BTS3002C and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 3.

  3. Replace the MCU and DRU and see if the alarm is cleared

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared.Please contact Huawei Customer Service Center.